Valve electric gentle start for compressed air, APR, series SYNTESI®

Additional information

Maximum operating temperature [°C]

50

Minimum operating temperature [°C]

-10

Valve gentle start serves for filling the system working compressed air, o action two-stage. supply signal control causes opening valve shut-off and Flow rate air through valve throttle. Po obtaining through pressure output ok. 40 ÷ 60% value pressure supply occurs switching valve and Flow rate air full cross-section od the connection inlet for output. removal signal control causes shut-off valve supply and venting the system working. valve gentle start found use in installations, in which occurs the need securing powered element actuating against sudden aeration, which can generate loads impact acting on element structural machine. excessive draw air with the connection output in during preliminary aeration the system working can disturb operation valve preventing its solid opening. Size: SY1, SY2. Connection: 1/8″ BSP female ÷ 1″. Supply pressure: 3 – 10 bar. additional Connection output: 1/8″ BSP female for size SY1, 1/4″ BSP female for size SY2, with the front and with the back.Operating temperature: od -10°C up to +50°C. Flow rate nominal: depending on size od 1250 l/min for 4800 l/min (at pressure 6.3 bar Δp = 1 bar).

List of product variants

Article numberProduct variant nameDNBARAvailabilityPriceQuantityActionsCatalogue
MW-5611A701Valve gentle startu elektryczny APR SY1 1/8 ELPN--In stock0 €
Enquiry
MW-5612A702Valve gentle startu elektryczny APR SY1 1/4 ELPN--In stock0 €
Enquiry
MW-5613A703Valve gentle startu elektryczny APR SY1 3/8 ELPN--In stock0 €
Enquiry
MW-5623A703Valve gentle startu elektryczny APR SY2 3/8 ELPN--In stock0 €
Enquiry
MW-5624A704Valve gentle startu elektryczny APR SY2 1/2 ELPN--In stock0 €
Enquiry
MW-5625A705Valve gentle startu elektryczny APR SY2 3/4 ELPN--In stock0 €
Enquiry
MW-5626A706Valve gentle startu elektryczny APR SY2 1 ELPN--In stock0 €
Enquiry

Do you need a larger quantity of products or a bespoke quote?

Valve gentle start serves for filling the system working compressed air, o action two-stage. supply signal control causes opening valve shut-off and Flow rate air through valve throttle. Po obtaining through pressure output ok. 40 ÷ 60% value pressure supply occurs switching valve and Flow rate air full cross-section od the connection inlet for output. removal signal control causes shut-off valve supply and venting the system working. valve gentle start found use in installations, in which occurs the need securing powered element actuating against sudden aeration, which can generate loads impact acting on element structural machine. excessive draw air with the connection output in during preliminary aeration the system working can disturb operation valve preventing its solid opening. Size: SY1, SY2. Connection: 1/8″ BSP female ÷ 1″. Supply pressure: 3 – 10 bar. additional Connection output: 1/8″ BSP female for size SY1, 1/4″ BSP female for size SY2, with the front and with the back.Operating temperature: od -10°C up to +50°C. Flow rate nominal: depending on size od 1250 l/min for 4800 l/min (at pressure 6.3 bar Δp = 1 bar).